Figure 5.5
Operational
Sequence for Starting Continuous Mode
Select continuous mode
Is the barrier guard closed?
Is the shaft in the neartop
position?
Have all operators released all
STOPONTOP buttons?
Have all operators released all
RUN buttons?
NOTE: The arming sequence guards against accidently starting operation in continuous mode.
12264
Yes
Yes
Select inch mode and position the
shaft to the neartop position
No
Yes
Has an operator pressed the ARM
CONTINUOUS button?
Have 5 seconds elapsed since
pushing ARM CONTINUOUS?
Has each operator pressed his
RUN buttons simultaneously, and
within 5 seconds for all stations?
Go to First Downstroke
Figure 5.6
No
Yes
No
No
Yes
Yes
No
Yes
No
No
Arming Sequence
Main Motor Forward
No