Manual
Voting Processor Firmware
Chapter 5
54
Figure 5.1
Cam
Limit Switch Settings
Near Top
Position
Run - On
Near Bottom
Zone
Upstroke
Anti - Repeat
before run-on contacts make, or the controller faults.
Run-on contacts must make (not necessarily at the same time)
before
Anti-repeat contacts must break for at least 70ms during
upstroke, then make before run-on contacts break, or the controller faults.
Anti-repeat contacts must make (not necessarily at the same time)
before run-on contacts break, or the controller faults.
Run-on contracts must break (not necessarily at the same time)
MAKE
MAKE
MAKE
BREAK
MAKE
MAKE
BREAK
MAKE
MAKE
MAKE
MAKE
BREAK
MAKE
MAKE
BREAK
BREAK
BREAK
BREAK
Down-
stroke
Near
Bottom
Up-
stroke
Near
Top
Run-On
Anti-
Repeat
Zone
Comments
Cam Linit Switch Settings
Refer to Diagnostic Messages, table 7.C. Hex codes 80 thru AA, for descriptions of faults caused
by cam limit switches.
12970
70 ms
NOTE:
Install two mechanically independent cam limit switch assemblies each with three cams and three
limit switches. Set the assemblies to similar settings according to the requirements of your press.
You can set cam limit switches to other configurations provided they meet the make/break conditions
listed below:
Downstroke
Top-Stop
-Check
Topstopcheck
contacts must make (not necessarily at the same time)
T
opstopcheck contacts break, or the controller faults.
T
opstopcheck contacts must break (not necessarily at the same time)
before antirepeat contacts break or the controller faults.
before T
opstopcheck contacts make or the controller faults.
Top-stop-
check
Table 5.A
Operation
of Cam Limit Switches
This
Cam
In this
Mode
W
ith these
Conditions
Provides the PM Module a Signal:
Anti
Repeat
Onthehop single
stroke
Run buttons released
past bottom
T
o allow a second stroke when run buttons
are pressed a second time
Runon
Inch and Microinch
(forward) and Single
stroke
Cam opens at neartop
position T
o turn OFF triac output for
stopontop (cycle stop)
Continuous
Cam opens at neartop
position after
stopontop command
Single stroke and
Continuous
Cam closes at
nearbottom position
T
o let operator release any depressed run
buttons without interrupting a single stroke
or continuous stroking
TopStop
Check
any
Cam closes during
stopontop
T
o energize a Brake Fault output to warn
that the brake is faulty (Hazardous
Condition)
Inch and
Microinch
(reverse)
Cam opens in neartop
position
T
o turn OFF solenoid outputs to stop the
cycle