Manual

Troubleshooting
Chapter 7
736
diagnostic message codes are displayed by indicators connected to module group 5, slot 1 (figure 6.18), or by displaying the corresponding
data table word using the industrial terminal.
Use this table in conjunction with figure 7.1 and figure references shown in parentheses.
T
ype of Message
N = Nonlatched
L = Latched
T = T
rip Condition
Code
P = at Powerup
Alt = Alternate chassis
Ethr = Either chassis
Top = T
op chassis
Bot = Bottom chassis
Binary
Diagnostic Message (figure References)
CodeTypeHex
1111 1100 FC N
Backplane error
. Replace chassis.
2
1111 1101 FD N
Hardware fault in 1771PM module.
2
1111 1110 FE N
Hardware fault in 1771PM module.
2
1111 1111 FF N
Powerup other 1771PM module.
Microinch Diagnostic Codes
(Examine module group 3, slot 1, bit 2, chassis A and B for MSB)
1 0101 1010
15A T
Microinch valve stem input is present though not configured.
1 0101 101
1 15B T Alt
Microinch valve stem input is present though not configured.
1 101
1 1100 1BC T
Microinch clutch pressure input is present though not configured.
1 101
1 1101 1BD T
Microinch clutch pressure input is present when triacs are of
f.
1 101
1 1110 1BE T
Microinch clutch pressure input is of
f when triacs are on.
1 101
1 1111 1BF T
Microinch clutch pressure input remains on after triacs turn of
f.
1 1
100 0000
1C0 T Ethr T
riac 8 is on when commanded of
f.
1 1
100 0001
1C1 T Ethr T
riac 9 is on when commanded of
f.
1 1
100 01
10 1C6 T Bot T
riac 8 is on when commanded of
f.
1 1
100 01
11 1C7 T Bot T
riac 9 is on when commanded of
f.
1 1
100 1
100 1CC T To p T
riac 8 is of
f when commanded on.
1 1
100 1
101 1CD T To p T
riac 9 is of
f when commanded on.
1 1
101 0010
1D2 T Ethr T
riac 8 is of
f when commanded on.
1 1
101 001
1 1D3 T Ethr T
riac is of
f when commanded on.