Manual

Troubleshooting
Chapter 7
735
diagnostic message codes are displayed by indicators connected to module group 5, slot 1 (figure 6.18), or by displaying the corresponding
data table word using the industrial terminal.
Use this table in conjunction with figure 7.1 and figure references shown in parentheses.
T
ype of Message
N = Nonlatched
L = Latched
T = T
rip Condition
Code
P = at Powerup
Alt = Alternate chassis
Ethr = Either chassis
Top = T
op chassis
Bot = Bottom chassis
Binary
Diagnostic Message (figure References)
CodeTypeHex
11
10 01
10 E6 T
Aux. valve stem signal of
f when triacs are on.
1
11
10 01
11 E7 T Alt
Aux. valve stem signal of
f when triacs are on.
1
11
10 1000
E8 T
Dump valve stem signal of
f when traics are on.
1
11
10 1001
E9 T Alt
Dump valve stem signal of
f when traics are on.
1
11
10 1010
EA T
Main valve stem signal remains on after triacs turn of
f.
1
11
10 101
1 EB T Alt
Main valve stem signal remains on after triacs turn of
f.
1
11
10 1
100 EC T
Aux. valve stem signal remain on after triacs turn of
f.
1
11
10 1
101 ED T Alt
Aux. valve stem signal remain on after triacs turn of
f.
1
11
10 1
110 EE T
Dump valve stem signal remains on after traics tuirn of
f.
1
11
10 1
111 EF T Alt
Dump valve stem signal remains on after traics tuirn of
f.
1
Hardware or Cable Fault
111
1 0000
F0 T Alt
Chassis power tripped or chassis restarted. (6.1, 6.6)
111
1 0001
F1 L
Lost communications between 1771PM modules. Reset latched message, check cables, or
cycle power
. (3.3)
111
1 0010
F2 L
Lost communications with PC. Reset latched mesage, check cables, or cycle power
. (3.3)
111
1 001
1 F3 L Alt
Lost communications with PC. Reset latched mesage, check cables, or cycle power
. (3.3)
111
1 0100
F4 N
Lost communications between 1771PM modules.
2
111
1 0101
F5 N
Hardware fault in 1771PM module. Replace it.
111
1 01
10 F6 N T
urn of
f backplane switch 1. (3.4)
111
1 01
11 F7 N
Hardware fault in 1771PM module.
2
111
1 1000
F8 N
Not used
111
1 1001
F9 N
Hardware fault in 1771PM module.
2
111
1 1010
FA N
1771PM modules must be same revision.
111
1 101
1 FB N
Hardware fault in 1771PM module. Replace it.