Manual

Troubleshooting
Chapter 7
727
Diagnostic message codes are displayed by indicators connected to module group 5, slot 1 (figure 6.18), or by
displaying the corresponding data table word using the industrial terminal.
Use this table in conjunction with figure 7.1 and figure references shown in parentheses.
T
ype of Message
N = Nonlatched
L = Latched
T = Trip
Condition
Code
P = at Powerup
Alt = Alternate chassis
Ethr = Either chassis
Top = T
op chassis
Bot = Bottom chassis
Hex
Code
Diagnostic Message (figure References)
Type
3D Alt T
(NO) RUN button bypass is open. Check wiring
3E N
Station signals present though not configured.
3F Alt N
Station signals present though not configured.
Station 4
(Figure 6.16)
40 N
Check configuration of RUN button signals. Make station active or bypassed
41 N
RUN button not released. Check (NO) contacts.
42 Alt N
RUN button not released. Check (NO) contacts.
43 N
RUN button not released. Check (NC) contacts.
44 Alt N
RUN button not released. Check (NC) contacts.
45
P
N
Make left and right active connections identical.
46 P N
(NC) RUN button is open. Check button or wiring.
47 P N
(NO) RUN button is shorted. Check button or wiring.
48 T
Active input changed from closed to open. Check wiring.
49 Alt T
Active input changed from closed to open. Check wiring.
4A T
(NC) RUN button bypass is open. Check wiring
4B Alt T
(NC) RUN button bypass is open. Check wiring
4C T
(NO) RUN button bypass is open. Check wiring
4D Alt T
(NO) RUN button bypass is open. Check wiring
4E
Not Used.
4F
Not Used
Inch button
(Figure 6.13)