Set PRT2 Communication Rate Select Jumper (JW6)
Use JW6 to set the communication rate for PRT2 at power-up.
Set the communication rate according to your application.
Important: You can also select the communication rate for PRT2 within
your program. The settings you select with PROG1 (page 10 -12) and
PROG2 (page 10 -13) override the jumper setting until the module is
powered down. The settings you select with MODE (page 11 -20)
override both the jumper and the PROG1 and PROG2 settings until the
module is powered down. If you use PROG1, PROG2, or MODE with the
ā€œEā€ option storage to save the port settings in the user EEPROM, the unit
then powers up with the stored configuration.
To set the communication rate for:
Se
t j
u
mp
er
:
āœ” your selection:
300 bit/s
600 bit/s
1200 bit/s
factory
setting
2400 bit/s
4800 bit/s
9600 bit/s
19.2k bit/s
Refer to Chapter 2 for more information regarding communication rates.