Instruction Manual

Chapter 3
Constructing a Data Highway or
Data Highway Plus Cable System
3-6
13. Attach the dropline to the 15-socket connector and secure each wire with a
bead of solder.
Important: In this step, take care so that you do not heat the shrink tubing
when soldering.
Connect this wire: To this pin number:
Blue conductor wire 6
Clear conductor wire 8
Drain wire 7
12
9
1
4
6
7
8
Pins
15 -socket Connector
Clear
Conductor
Wire
Small -diameter
Shrink Tubing
Drain Wire
Blue
Conductor
Wire
Large -diameter
Shrink Tubing
Dropline
Right -angle
Hood
10805
15
Go to step 15.