Instruction Manual
Constructing a Data Highway or
Data Highway Plus Cable System
Chapter 3
3-5
11. Connect the dropline to the 3-position terminal block connector.
Secure this wire: To this terminal:
Clear conductor wire 1
Drain wire SH
Blue conductor wire 2
Clear
Shield
Blue
Clear
Shield
Blue
1
SH
2
1
SH
2
Terminals on
3 -pin terminal block
Twinaxial cable
19603
Go to step 15.
12. Connect the dropline to the 9-pin electrical connector.
Connect this wire: To this pin number:
Blue conductor wire 5
Drain wire 7
Clear conductor wire 1
Blue
Drain
Clear
Twinaxial Cable
5
7
1
18767
Go to step 15.