User Manual
D-8 SCANport Objects
Instance Attributes
SCANport Pass-Through Warning Object (Continued)
Attribute
ID
Access
Rule
Name Data Type Description
0 Get Read Warning
Queue Entry Full/All
Info
STRUCT of
Warning Text ARRAY of BYTE 16 character string (no length
information, no terminating null)
Warning Code WORD Fault Code
Warning Time
Stamp (Time
Stamps not
available in all
products)
STRUCT
BYTE 1/100 Second (0 - 99)
BYTE Second (0 - 59)
BYTE Minute (0 - 59)
BYTE Hour (0 - 23)
BYTE Day of Week (0 - 6)
(1)
BYTE Date (1 - 31)
BYTE Month (1 - 12)
BYTE Year (0 - 99)
(2)
128 Get Warning Code and
Time Stamp (Time
Stamps not
available in all
products)
STRUCT of
Warning Code WORD Fault Code
Warning Time
Stamp (Time
Stamps not
available in all
products)
STRUCT of
BYTE 1/100 Second (0 - 99)
BYTE Second (0 - 59)
BYTE Minute (0 - 59)
BYTE Hour (0 - 23)
BYTE Day of Week (0 - 6)
(2)
BYTE Date (1 - 31)
BYTE Month (1 - 12)
BYTE Year (0 - 99)
(3)
129 Get Read Warning Text
String Only
ARRAY of BYTE 16 character string (no length
information, no terminating null).
(1)
Sunday is a value of zero.
(2)
Year is an offset from 1990.