Specifications

6 Rockwell Automation Publication 1769-TD006E-EN-P - January 2015
1769 Compact I/O Modules Specifications
Analog I/O Modules
Choose analog, thermocouple, or RTD modules for these features:
Individually configurable channels
Ability to individually enable and disable channels
On-board scaling
Auto calibration of inputs
Online configuration
Selectable input filters
Over-range and under-range detection and indication
Selectable response to a broken input sensor
Selectable power source
Input modules offer both single-ended or differential inputs
Ability to direct output device operation during an abnormal condition
High accuracy ratings
The data can be configured on board each module as:
Engineering Units in volts or milliamps.
Scaled-for-PID.
Percent of range.
Raw/Proportional Data for maximum resolution.
Specialty I/O Modules
These specialty modules are available.
Cat. No. Description
1769-ARM Use a 1769-ARM address reserve module to reserve module slots. After creating an I/O configuration and user
program, you can remove and replace any I/O module in the system with a 1769-ARM module once you inhibit the
removed module in RSLogix 5000 programming software.
1769-ASCII The 1769-ASCII module, a general purpose two-channel ASCII interface, provides a flexible network interface to a
wide variety of RS-232, RS-485, and RS-422 ASCII devices. The module provides the communication connections to
the ASCII device.
1769-BOOLEAN Use the 1769-BOOLEAN module in applications that require repeatability, such as material handling and packaging,
when there is a requirement to activate an output based on an input’s transition. If the Boolean expression is true, the
output is directed to the ON state. If the Boolean expression is false, the output channel is directed to the OFF state.
There are four operators that you can configure as OR, AND, XOR, or none.
1769-HSC Use the 1769-HSC module when you need:
a counter module that is capable of reacting to high-speed input signals.
to generate rate and time-between-pulses (pulse interval) data.
one or two channels of quadrature or four channels of pulse/count inputs.
1769-SM1 The Compact I/O to DPI/SCANport module connects to PowerFlex 7-class drives, other DPI-based host devices, and
SCANport-based host devices such as 1305 and 1336 PLUS II drives.
1769-SM2 The Compact I/O to DSI/Modbus module connects to PowerFlex 4-class drives and to other Modbus RTU slave devices,
such as PowerFlex 7-class drives with 20-COMM-H RS485 HVAC adapters.