Rockwell Automation Publication 1769-TD005I-EN-P - August 2014 59
CompactLogix Controllers Specifications
Communicate with Other Communication Devices
The controller can communicate with these communication devices.
1763 MicroLogix Ye s No Yes
(4)
Yes Ye s
1764 MicroLogix Ye s No Yes
(4)
Yes Ye s
1772 PLC-2
®
Yes
1775 PLC-3
®
Yes
5250 PLC-5/250 No Yes
(1) A non-EtherNet/IP controller requires a 1761-NET-ENI interface to connect to an EtherNet/IP network. This interface is only a messaging bridge.
(2) In the CompactLogix system, use either a 1769-SDN scanner (control I/O and send/receive messages) or a 1761-NET-DNI interface (messaging bridge).
(3) The CompactLogix 5370 L1 controllers cannot access a DeviceNet network and, therefore, cannot communicate with other controllers on a DeviceNet network.
(4) The CompactLogix 5370 controllers do not have an embedded serial port. You must add external modules to communicate over an RS-232 (DF1) network.
(5) The CompactLogix 5370 controllers do not have an embedded serial port. You must add external modules to communicate over a DH-485 network.
(6) The Ethernet PLC-5 controller must be series C, firmware revision N.1 or later; series D, firmware revision E.1 or later; or series E, firmware revision D.1 or later.
(7) The 1785-ENET Ethernet communication interface module must be series A, firmware revision D or later.
(8) The PLC-5, SLC, and MicroLogix processors appear as I/O points to the Logix controller. Use the appropriate DeviceNet interface for the controller.
(9) Use a 1747-L55x controller with OS501 or later.
Communication Device EtherNet/IP Network
(1)
(1) A non-EtherNet/IP controller requires a 1761-NET-ENI interface to connect to an EtherNet/IP network. This interface is only a messaging bridge.
ControlNet Network DeviceNet Network
(2)
(2) In the CompactLogix system, use either a 1769-SDN scanner (control I/O and send/receive messages) or a 1761-NET-DNI interface (messaging bridge).
Linking device (only ControlLogix controllers) 1788-EN2DN 1788-CN2DN
1788-CN2FF
1788-EN2DN
(3)
1788-CN2DN
(3) The 1788-EN2DN does not support safety communication (CIP Safety).
PCMCIA card 1784-PCC 1784-PCD
PCI card 1784-PCIC
1784-PCICS
1784-PCID
1784-PCIDS
1784-CPCIDS
Drives SCANport
module 1203-FM1
1203-FB1
(4)
(4) Use a CIP generic MSG instruction to communicate with the 1203-FM1 SCANport module on a DIN rail that is remote to the controller. The remote DIN rail also requires a 1794-ACN15 or 1794-ACNR15
ControlNet adapter module.
Communication module 1203-CN
(5)
1770-KFC15
1770-KFCD15
1747-KFC15
(5) Use the generic module configuration to configure the 1203-CN1 module and a CIP generic MSG instruction to communicate with the module.
1770-KFD
1770-KFG
Communication card 1784-PKTCS
1784-KTCS
1784-KTCX15
1784-PKTX
1784-PKTXD
USB communication device 1784-U2CN 1784-U2DN
Controller EtherNet/IP
Network
(1)
ControlNet Network DeviceNet
Network
(2)
RS-232 (DF1)
Network
DH-485 Network