Manual
Publication 1762-UM002A-EN-P - July 2002
Module Data, Status, and Channel Configuration 3-21
Figure 3.8 Effective Resolution Versus Input Filter Selection for Type J
Thermocouples Using 10, 50, and 60 Hz Filters
0
0.1
0.2
0.3
0.4
-400 -200 0 200 400 600 800 1000 1200
10 Hz
50 Hz
60 Hz
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
-400 0 400 800 1200 1600 2000
10 Hz
50 Hz
60 Hz
Effective Resolution (°C)
Temperature (°C)
Effective Resolution (°F)
Temperature (°F)