Programmer (HHP) User guide

Chapter 19
Common Procedures
19–6
If you want to create a new program, you need to first clear the current
program from the controller. Follow the steps below.
1. Enter the menu and choose the option
CLEAR PROG.
6
MENU
I
ENT
C L E A R P R O G R A M ?
Y E S [ E N T ] N O
E S C ]
2. Clear the program from the controller.
ENT
C L E A R P R O G R A M ?
C L E A R I N G . . . . .
Once the program is cleared, the menu options are displayed. You can
return to the previous functional areas by pressing
ESC.
Important: All program configuration settings are returned to their defaults.
See page 18–1 for information of changing the default settings.
Follow the steps below to change the controllers baud rate. (The default is
9600 baud.)
Important: These steps apply only to programs configured for Series A and
B MicroLogix 1000 discrete controllers. If you have configured
your program for Series C or later discrete controllers or for
MicroLogix analog controllers, see page 19–7 for directions on
changing the baud rate.
1. Enter the menu and choose the option
BAUD RATE.
7
MENU
I
ENT
9 6 0 0
2 4 0 0
The arrow points to the controllers current baud rate.
Clearing a Program from the
Micro Controller
Changing the Micro
Controllers Baud Rate