Programmer (HHP) User guide

Chapter 14
Using High-Speed Counter Instructions
14–11
Bidirectional Counter with Reset and Hold (Pulse/direction)
Input State
High-Speed
Count r
Input Count
(I/0)
Input
Direction (I/1)
Input Reset
(I/2)
Input Hold
(I/3)
HSC Rung
High-Sp
ee
d
Counter
Action
Turning
Off-to-On
Off
Off, On, or
Turning Off
Off True Count Up
Turning
Off-to-On
On
Off, On, or
Turning Off
Off True Count Down
NA NA
Off, On, or
Turning Off
NA False Hold Count
NA NA
Off, On, or
Turning Off
On NA Hold Count
Off, On, or
Turning Off
NA
Off, On, or
Turning Off
NA NA Hold Count
NA NA Turning On NA NA Reset to 0
NA (Not Applicable)
Bidirectional Counter (Up/down count)
Input State
High-Sp d
Input Up
Count (I/0)
Input Down
Count (I/1)
HSC Rung
High-Sp
ee
d
Counter Action
Turning
Off-to-On
Off, On, or
Turning Off
True Count Up
Off, On, or
Turning Off
Turning
Off-to-On
True Count Down
NA NA False Hold Count
NA (Not Applicable)
Bidirectional Counter with Reset and Hold (Up/down count)
Input State
High-Sp
ee
d
Count r
Input Up
Count (I/0)
Input Down
Count (I/1)
Input Reset
(I/2)
Input Hold
(I/3)
HSC Rung
High-Sp
ee
d
Counter
Action
Turning
Off-to-On
Off, On, or
Turning Off
Off, On, or
Turning Off
Off True Count Up
Off, On, or
Turning Off
Turning
Off-to-On
Off, On, or
Turning Off
Off True Count Down
NA NA
Off, On, or
Turning Off
NA False Hold Count
NA NA
Off, On, or
Turning Off
On NA Hold Count
Off, On, or
Turning Off
Off, On, or
Turning Off
Off, On, or
Turning Off
NA NA Hold Count
NA NA Turning On NA NA Reset to 0
NA (Not Applicable)