Software User Manual FRN 1.2 Owner manual

Publication 1758-UM002D-EN-P - October 2010
138 DataSite Flow Configuration Utility (DS FloConfig)
Cut-off Differential
When the differential pressure is lower than the value entered in the
Cut-off Differential box, the DataSite controller will consider any flow
as inexistent.
There will be a cutoff alarm in the Meter Run window, and the flow
rates become zero when this happens.
Tap Location
This is the location of the flange taps. It could be on the upstream or the
downstream of the orifice plate.
Orifice Plate Parameters for AGA3 Standard
Orifice Material and Tube Material
Specify the material of the orifice plate and pipe tube by selecting it
from the drop-down lists. These three materials are listed:
304 and 316 stainless steel
Carbon steel
Monel
Orifice Diameter
This is the inner diameter of the orifice plate measured at the reference
temperature specified in the Reference T box.