User Manual Manual
Rockwell Automation Publication 1757-UM012A-EN-P - July 2011 159
Appendix
C
Fieldbus Status Codes
for RSLogix 5000 Projects
Introduction
The status codes in this appendix are in the controller tags of projects created in
the RSLogix 5000 programming software.
Input Parameters
Topic Page
Input Parameters 159
Output Parameters 164
Table 24 - FFLD1:0:I.In[0].xxxxxx
Fieldbus Status Logix Status - FFLD1:0:I.In[0].xxxxxx
Quality Sub-status Limits Quality Substatus WindupL WindupH Init
Primary
Initializing Initiate
Fault State
Bad Non-Specific Not Limited 0 0 0 0 0 0 0
Low Limited 0 0 1 0 0 0 0
High Limited 0 0 0 1 0 0 0
Constant 0 0 1 1 0 0 0
Configuration Error Not Limited 0 1 0 0 0 0 0
Low Limited 0 1 1 0 0 0 0
High Limited 0 1 0 1 0 0 0
Constant 0 1 1 1 0 0 0
Not Connected Not Limited 0 2 0 0 0 0 0
Low Limited 0 2 1 0 0 0 0
High Limited 0 2 0 1 0 0 0
Constant 0 2 1 1 0 0 0
Device Failure Not Limited 0 3 0 0 0 0 0
Low Limited 0 3 1 0 0 0 0
High Limited 0 3 0 1 0 0 0
Constant 0 3 1 1 0 0 0