Table 4.25 Channel 0 through 7 Status Word (I:e.8 through I:e.15) - Bit Definitions
Bit(s) Define These bit settings Indicate this
1514131211109876543210
0 through 3 Input type
status
0000100Ω Pt RTD (385)
0001200Ω Pt RTD (385)
0010500Ω Pt RTD (385)
00111000Ω Pt RTD (385)
0100100Ω Pt RTD (3916)
0101200Ω Pt RTD (3916)
0110500Ω Pt RTD (3916)
01111000Ω Pt RTD (3916)
1000
10
Ω Cu RTD (426)
(1)
1001
120
Ω Ni RTD (618)
(2)
1010120Ω Ni RTD (672)
1011604Ω NiFe RTD (518)
1100150Ω Resistance Input
1101500Ω Resistance Input
11101000Ω Resistance Input
11113000Ω Resistance Input
4 through 5 Data format
status
00
Engineering units x 1
(3)
01
Engineering units x 10
(4)
10 Scaled-for-PID
11 Proportional Counts
6 through 7 Broken input
status
00 Set to Zero
01 Set to Upscale
10 Set to Downscale
11 Not used
8 Temperature
units status
0
Degrees C
(5)
1
Degrees F
(5)
9 through 10 Filter frequency
status
00 28 Hz
01 50/60 Hz
10 800 Hz
11 6400 Hz
11 Channel enable
status
0 Channel Disabled
1 Channel Enabled
12 Calibration Error
0 OK
1 Error
13 Broken input
0 OK
1 Error
14 Out-of-range
error status
0 OK
1 Error
15 Configuration
Error
0
OK
1
Error
(1) Actual value at 0°C is 9.042Ω per SAMA standard RC21-4-1966.
(2) Actual value at 0°C is 100Ω per DIN standard.
(3) Values are in 0.1 degree /step or 0.1Ω/step for all resistance input types, except 150Ω. For the 150Ω resistance input type, the values are in 0.01Ω/step.
(4) Values are in 1 degree /step or 1Ω/step for all resistance input types, except 150Ω. For the 150 Ω resistance input type, the values are in 0.1Ω/step.
(5) This bit is cleared (0) when a resistance device, such as a potentiometer, is selected.