User Manual Owner's manual
Publication 1746-UM614B-EN-P - September 2007
10 Module Overview
General Description
The module stores digitally-converted thermocouple and/or millivolt
(mV) analog data in its image table for retrieval by all fixed and
modular SLC 500 processors. The module supports connections from
any combination of up to four thermocouple and/or mV analog
sensors.
Input Ranges
The following tables define thermocouple types and associated
temperature ranges and the millivolt analog-input signal ranges that
each of the module’s input channel supports.
Refer to the specifications in Appendix A to determine the practical
temperature range of your thermocouple.
Each input channel is individually configurable for a specific input
device, and provides open-circuit, over-range, and under-range
detection and indication.
Thermocouple Temperature Ranges
Type °C Temperature Range °F Temperature Range
C 0…2317 32… 4201
D 0… 2317 32…4201
J -210…760 -346…1400
K -270…1370 -454…2498
T -270…400 -454…752
B 300…1820 572…3308
E -270…1000 -454…1832
R 0…1768 32…3214
S 0…1768 32…3214
N 0…1300 32…2372
CJC Sensor 0…85 32…185
Millivolt Input Ranges
-50…50 mV
-100…100 mV