4-32 Configuration and Programming
M0:e.3 /8-15 Initial Outputs (Dynamic)
The Initial Output is the starting position output pattern. It determines
the output pattern until the preset of the first Valid Step is reached.
Initial Outputs are applied when the Function Control bit makes a 0 to
1 transition and remains in effect until the first Valid Step is reached.
The Initial Output Pattern is not applied again unless:
• the Function Control bit makes another 0 to 1 transition
• reset occurs with the Sequencer Reset bit (M0:e.1/0)
Valid Steps for Sequencer Mode Corresponding Step
0 disabled
1 enabled
Preset
Number
Desired
Trigger
Preset Value
Outputs
(1)
(1)Bits 0-3 are Physical Outputs. Bits 4 -7 are Soft Outputs.
76543210
Initial Output 00000000
1 10,000 9,999 00000001
2 20,000 19.999 00000010
3 27,000 26,999 00000011
Valid Steps 1–16, Word 2
Initial Outputs and Valid Steps 17–24, Word 3
M0:e.2
M0:e.3
Bit Number (decimal) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
steps
1–16
steps 17–24
Initial Outputs and Valid Steps 17–24, Word 3
M0:e.3
Initial
Outputs
Bit Number (decimal) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Initial
Outputs for
Soft Outputs
Initial Outputs for
Physical Outputs
Repeat