User guide

Publication 1746-UM006B-EN-P - August 2005
Module Overview 1-3
Operating Modes
The module operates in 3 modes:
Range mode
Rate mode
Sequencer mode
Specific operating mode information is contained in Chapter 2,
Module Operation. The following information summarizes the
module’s operating modes.
Range Mode
In the Range Mode, you define a group of count ranges and define
the outputs to be active when the Accumulated Count value is within
each range. In this mode, the module offers:
up to 12 ranges
dynamically configurable ranges
ring or linear counter operation
input rate calculation
direct SLC processor control of unused outputs
Rate Mode
In the Rate Mode, you define a group of rate ranges and
corresponding outputs. When the Rate Measurement is within each
defined range, the corresponding outputs are active. In this mode, the
module offers:
Rate Periods from 10 ms to 2.55 seconds
input rates up to 32,767 Hz in either direction
up to 12 ranges
ring or linear counter operation
dynamically configurable Rate Period and range values
IMPORTANT
Appendixes D and E contain blank worksheets to
assist you when configuring your module. Appendix
D contains worksheets for Range and Rate Mode
operation. Appendix E contains worksheets for the
Sequencer Mode operation.