Installation Instructions 1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect Catalog Numbers 1732E-12X4M12QCDR, 1732E-12X4M12P5QCDR, 1732E-16CFGM12QCR, 1732E-16CFGM12P5QCR, 1732E-16CFGM12QCWR, 1732E-16CFGM12P5QCWR Table of Contents Topic Page Important User Information 2 Environment and Enclosure 3 Preventing Electrostatic Discharge 3 Overview 4 Catalog Number Explanation 5 Install the Module 6 Set the Network Address 6 Mount the Module 7 Product Dimensions 7 Connect the I/O,
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.rockwellautomation.
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect 3 Environment and Enclosure ATTENTION: This equipment is intended for use in overvoltage Category II applications (as defined in IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating. This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR 11.
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect Additional Resources Resource Description ArmorBlock 2-Port EtherNet with Diagnostics and QuickConnect Wiring Diagrams, publication 1732E-WD004 Detailed description of how to wire your 1732E-12X4M12QCDR or 1732E-12X4M12P5QCDR module. ArmorBlock WeldBlock 2-Port Ethernet Self-configurable with QuickConnect Wiring Diagrams, publication 1732E-WD005 Detailed description of how to wire your 1732E-16CFGM12QCWR or 1732E-16CFGM12P5QCWR module.
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect 5 Module Identification 1732E-16CFGM12QCWR shown Function earth(2) LED status indicators LINK 1 EtherNet/IP D-code M12 connector PORT 1 MOD LINK 2 NET PORT 2 EtherNet/IP D-code M12 connector Node address switches M12 style I/O connectors M12 style I/O connectors Mini-style auxiliary power out Mini-style auxiliary power in Protective earth(1) 45758 AUX POWER (1) Protective Earth is provided for the grounding of field devices and
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect Catalog Number Description 1732E-16CFGM12P5QCR 16 channel 24V DC self-configurable digital I/O dual-port Ethernet module with QuickConnect 1732E-16CFGM12QCWR 16 channel 24V DC self-configurable digital I/O dual-port Ethernet metal WeldBlock module with QuickConnect 1732E-16CFGM12P5QCWR 16 channel 24V DC self-configurable digital I/O dual-port Ethernet metal WeldBlock module with QuickConnect Network Connector Dual D-code M12 Auxiliary Powe
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect 7 Set Network Address Example shows default node address set at 163. 45759 When the switches are set to a valid number, the I/O block’s IP address is 192.168.1.xxx (where xxx represents the number set on the switches). The I/O block’s subnet mask is 255.255.255.0 and the gateway address is set to 0.0.0.0.
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect Module Dimensions 45 mm (1.77 in.) 60.4 mm (2.38 in.) 28 mm (1.1 in.) LINK 1 PORT 1 MOD LINK 2 NET PORT 2 200 mm (7.87 in.) 189.6 mm (7.46 in.) AUX POWER 45760 Front view Side view Mount the Module in High Vibration Areas If you mount the module in an area that is subject to shock or vibration, we recommend you use a flat and a lock washer to mount the module.
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect 9 High Vibration Area Mounting Lock washer Flat washer 44766 Connect the I/O, Network and Auxiliary Cables to the Module The ArmorBlock EtherNet/IP family has 5-pin micro-style connectors. We provide caps to cover the unused connectors on your module. Connect the quick-disconnect cord sets you selected for your module to the appropriate ports.
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect Micro-style 5-Pin Output Female Connector 1 2 5 4 3 44807 For 1732E-12X4M12QCDR and 1732E-12X4M12P5QCDR only (View into connector) Pin 1 Not used Pin 2 Output B Pin 3 Return Pin 4 Output A Pin 5 PE Self-configuring Modules The 1732E-16CFGM12QCR, 1732E-16CFGM12P5QCR, 1732E-16CFGM12QCWR, and 1732E-16CFGM12P5QCWR self-configuring modules contain both input and output functionality.
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect 11 I/O Self-configure Circuitry 43601 EtherNet/IP Connector D-Code Micro Network Female Connector 5 1 4 2 3 (View into connector 1) Pin 1 M12_Tx+ Pin 2 M12_Rx+ Pin 3 M12_TxPin 4 M12_RxPin 5 Connector shell shield GND 45793 (View into connector 2) Pin 1 M12_Rx+ Pin 2 M12_Tx+ Pin 3 M12_RxPin 4 M12_TxPin 5 Connector shell shield GND 3 2 4 1 5 45794 IMPORTANT Use the 1585D–M4DC–H: Polyamide small body unshielded or the 1585D–M4DC–SH: Zi
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect Enable QuickConnect To enable QuickConnect for the Ethernet ports, use the RSLogix 5000 software Module QuickConnect tab and check the Enable QuickConnect option. For more information on the QuickConnect system set up, refer to Ethernet QuickConnect Application Technique, publication ENET-AT001. After the QuickConnect feature is set to "on", the module must be power cycled. QuickConnect is active during the next connection.
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect 13 Auxiliary Power Connector The 1732E-12X4M12QCDR, 1732E-16CFGM12QCR, and 1732E-16CFGM12QCWR modules use 4-pin auxiliary power connections. Attach the mini-style 4-pin connector to the mini-style 4-pin receptacle as shown below.
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect Auxiliary Power is based on a 4-pin and 5-pin connector system and is used to provide 24V DC power to I/O modules and other devices. Running separate power to these devices is most typically used for I/O devices with output connections to prevent power supply interruption due to switching of outputs. However, some devices require separate auxiliary power to power them regardless of the presence of outputs.
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect 15 Refer to On-Machine Connectivity Catalog, publication M117-CA001, for Rockwell Automation cable and cord set offerings or use the configuration tools available at www.rockwellautomation.com/en/e-tools/. External Repository for Random Data (ERRD) The QuickConnect modules provide onboard nonvolatile memory, of up to 6 Kbytes, for storing block-specific data such as Tool ID and counter value. You can read from and write to the module memory.
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect Stop command Service Code Class ID Instance ID Attribute ID 07 (hex) 6E (hex) 1 1 Interpret LED Indicators This module has the following indicators: • Network, Module, and Link status indicators for EtherNet/IP • Module Power indicator • Individual I/O status indicators for inputs and outputs 1732E-16CFGM12QCR/ 1732E-16CFGM12QCWR Link status indicator Module status indicator PORT 1 LINK 1 LINK 2 MOD NET 1732E-12X4M12QCDR Link st
32E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect 1732E-16CFGM12P5QCR/ 1732E-16CFGM12P5QCWR Link status indicator Module status indicator PORT 1 LINK 1 LINK 2 MOD NET 1732E-12X4M12P5QCDR Link status indicator Network status indicator PORT 2 17 Module status indicator PORT 1 LINK 1 LINK 2 MOD NET PORT 2 Network status indicator Input status indicator I/O status indicator Output status indicator Power status indicator AUX POWER AUX POWER 46201 Indicator Status for Modules
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect Indicator Status for Modules Network status Network link status Power status Digital output status Digital input status (1) Status Description Off The device is not initialized or the module does not have an IP address. Flashing green The device has no CIP connections. The device has an IP address, but no CIP connections are established. Green The device is online, has an IP address, and CIP connections are established.
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect 19 Specifications 1732E ArmorBlock 2-Port EtherNet Module Input Attribute Value Number of inputs 12 – 1732E-12x4M12QCDR, 1732E-12x4M12P5QCDR 16 – all other modules Input type Sink, 24V DC Voltage, off-state input, max 5V DC Voltage, on-state input, max 30V DC Voltage, on-state input, nom 24V DC Voltage, on-state input, min 12V DC Current, off-state input, max 1.
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect 1732E ArmorBlock 2-Port EtherNet Module Output Attribute Value Current per module, max 2.0 A – 1732E-12X4M12QCDR, 1732E-12X4M12P5QCDR 8.0 A – all other modules Leakage current, off-state output, max 0.5 mA – 1732E-12X4M12QCDR, 1732E-12X4M12P5QCDR 50 μA – all other modules Surge current per output, min 1.
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect 21 General Specifications Attribute Value Enclosure type rating Meets IP65/66/67/69K (when marked), and Type 4X Indoor Use Only, with receptacle dust caps or cable termination Wiring category(1) 1 - on signal ports 1 - on power ports 1 - on communications port Onboard memory type Ferroelectric Nonvolatile RAM (FRAM) Onboard memory, capacity, max 6 Kbytes (1) Use this Conductor Category information for planning conductor routing.
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect Environmental Specifications Attribute Value Radiated RF immunity IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 Mhz 1V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz EFT/B immunity IEC 61000-4-4: ±3 kV @ 5 kHz on power ports ±3 kV @ 5 kHz on signal ports ±3 kV @ 5 kHz on communications ports Surge transient immunity IEC 61000-4-5
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect 23 Notes: Publication 1732E-IN010C-EN-E - June 2013
Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellautomation.com/support/, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools.