User guide

Bulletin 161
17
Parameter
number
Function Basic
value
Setting range Input
Basic parameters
A01
Frequency command select 01 00: Frequency Pot
01: Input O/OI
02: Param.
F01/A20
A02
Start command select
01 01: Input [FW]/[RV]
02: RUN key
A03
Base frequency 50 50 - 360 Hz
A04
Maximum frequency 50 50 - 360 Hz
Analog input reference adjustment
A11
Frequency at the minimum set value 0 - 360 Hz
A12
Frequency at the maximum set value 0 0 - 360 Hz
A13
Analog input minimum 0 0 - 100%
A13
Analog input maximum 100 0 - 100%
A15
Start condition 01
00: Minimum speed
01: 0 Hz start
A16
Analog input filter setting 8 1 (max. filter,
slow response) to
8 (min. filter,
fast response)
Pre-set frequencies
A20
Frequency command if 02 has been entered
under parameter
A01
0.0 0 - 360 Hz
A21
1. Preset Frequency 0 0 - 360 Hz
A22
2. Preset Frequency 0 0 - 360 Hz
A23
3. Preset Frequency 0 0 - 360 Hz
A24
4. Preset Frequency 0 0 - 360 Hz
A25
5. Preset Frequency 0 0 - 360 Hz
A26
6. Preset Frequency 0 0 - 360 Hz
A27
7. Preset Frequency 0 0 - 360 Hz
A28
8. Preset Frequency 0 0 - 360 Hz
A29
9. Preset Frequency 0 0 - 360 Hz
A30
10. Preset Frequency 0 0 - 360 Hz
A31
11. Preset Frequency 0 0 - 360 Hz
A32
12. Preset Frequency 0 0 - 360 Hz
A33
13. Preset Frequency 0 0 - 360 Hz
A34
14. Preset Frequency 0 0 - 360 Hz
A35
15. Preset Frequency 0 0 - 360 Hz
A38
Jog Frequency 1.0 0.5 – 9.9 Hz
A39
Jog Stop Mode 00 00: Coast
01: Ramp
02: DC brake