Manual

Appendix
A
Specifications
Electrical
Supply Voltage Supplied by Drive
Power Consumption 1.4 Watts (280 mA) maximum
Environmental
Ambient Temperature
Operating 0 to 65° C (32 to 149° F)
Storage 40 to 85° C (40 to 185° F)
Relative Humidity 0 to 95% non-condensing
Vibration 1.0 G Operational
2.0 G Non-operational
Shock 15.0 G Operational
30.0 G Non-operational
Altitude 1,000 m (3,300 ft.) without derating
Communications
Baud Rate 500 kBaud
Protocol Drivecom 20 (21)
Mechanical
Dimensions are in Millimeters and (inches)
(1)
Required for module removal.
(2)
Module adds this dimension to the overall drive depth.
(3)
Required for connecting cable
(2)
21.4
(0.85)
(1)
17.34
(0.68)
(3)
60
(15)