Manual

Publication 0160-5.5 - September 1997
B-28 DeviceNet Information
Configuration Assembly Data
Formats (Continued)
Instance 191 Data Format (Fixed Configuration Assembly – All Preset Speed Models)
Config Num.
Parameter
Number
Description Size Config Num.
Parameter
Number
Description Size
1 30 Accel Time 1 2 18 47 Output Configuration 1
2 31 Decel Time 1 2 19 48 Output Threshold 2
3 32 Minimum Frequency 1 20 49 PWM frequency 1
4 33 Maximum Frequency 2 21 50 Restart Tries 1
5 34
Stop Mode Select
122 51 Restart Time 2
6 35 Base Frequency 2 23 61 Preset Frequency 0 2
7 36 Base Voltage 2 24 62 Preset Frequency 1 2
8 37 Maximum Voltage 2 25 63 Preset Frequency 2 2
9 38 Boost Select 1 26 64 Preset Frequency 3 2
10 39 Skip Frequency 2 27 65 Preset Frequency 4 2
11 40 Skip Frequency Band 1 28 66 Preset Frequency 5 2
12 41 Motor Overload Select 1 29 67 Preset Frequency 6 2
13 42 Motor Overload Current 2 30 68 Preset Frequency 7 2
14 43 Current Limit 1 31 69 Accel Time 2 2
15 44 DC Hold Time 1 32 70 Decel Time 2 2
16 45 DC Hold Voltage 1
17 46
Input Mode
1
!
!
Instance 192 Data Format (Fixed Configuration Assembly – All Signal Follower Models)
Config Num.
Parameter
Number
Description Size Config Num.
Parameter
Number
Description Size
1 30 Accel Time 1 2 13 42 Motor Overload Current 2
2 31 Decel Time 1 2 14 43 Current Limit 1
3 32 Minimum Frequency 1 15 44 DC Hold Time 1
4 33 Maximum Frequency 2 16 45 DC Hold Voltage 1
5 34
Stop Mode Select
117 46
Input Mode
1
6 35 Base Frequency 2 18 47 Output Configuration 1
7 36 Base Voltage 2 19 48 Output Threshold 2
8 37 Maximum Voltage 2 20 49 PWM frequency 1
9 38 Boost Select 1 21 50 Restart Tries 1
10 39 Skip Frequency 2 22 51 Restart Time 2
11 40 Skip Frequency Band 1 23 53 S-Curve 1
12 41 Motor Overload Select 1
! !
!
ATTENTION: Changing this parameter value may cause unpredictable network conditions, resulting in equipment damage, personal injury, or death.
Ensure that you understand how changing this parameter affects your application.