User guide

48
Power Distribution and DS Option
07
1
03
2345678914
0303030303030202
TABLE 1
TABLE 1
TABLE 1
TABLE 1
03
10
03
1112
02
13
01
15
01
16
01
17
0401
18
TABLE 1
2
3
1
3
2
6
5
14
3
2
1
5
6
4
CHASSIS
GENERAL NOTES:
-INDICATES TB4 TERMINAL BLOCK.
-INDICATES TERMINAL ON INDIVIDUAL
COMPONENTS.
4. COIL AND CONTACT CROSS REFERENCING - NUMBERS ADJACENT TO
COIL AND UNDER CONTACT INDICATE SHEET AND LINE NUMBERS.
-INDICATES LINE NO. 3.
-INDICATES SHEET NO. 1.
OFF-PAGE CROSS REFERENCING - NUMBERS ADJACENT TO SOURCE
AND DESTINATION SYMBOLS INDICATE SHEET AND LINE NUMBERS.
-INDICATES SHEET NO. 1.
-INDICATES LINE NO. 24.
2. * -INDICATES COMPONENTS SUPPLIED BY OTHERS.
- BUILDING GROUND TO BE GROUNDED
- POWER EQUIPMENT GROUND
1-3
TO 1-24
4
FROM 1-24
1-24
1-3
3.
1.
TE
PE
- CHASSIS CONNECTION.
BY CUSTOMER.
- SIGNAL COMMON
2-18
-UNDERSCORED TEXT LINE INDICATES
A NORMALLY CLOSED CONTACT.
FLA
REFER TO MOTOR NAMEPLATE
RPM (BASE)
MOTOR DATA
HP
VOLTS
FOR EXACT DATA.
MOTOR *
(T2)
(T1)
(G)
(T3)
AC
1
INSTRUCTION MANUAL PUBLICATION 0160-5.15
FOR FURTHER DRIVE INFORMATION, REFER TO
BULLETIN 160 SMART SPEED CONTROLLER
BR+ BR-
. HP
VOLTS
AMPS
2
4
3
5
NOTE: MOTOR FLA MUST NOT
EXCEED DRIVE AMP RATING.
TERMINAL BLOCK TB2
-DC+DC GRD
U
VW
TERMINAL BLOCK TB1
FOR DETAILED INFORMATION,
(INTERFACE CONTROL BOARD)
TERMINAL BLOCK TB2
REFER TO CONTROL OPTIONS
GRD
R
ST
L3
L2
L3'
L2'
L1
L1'
C-300358-2
WS\STD\300358\02-01
1
2
SCHEMATIC, BULLETIN 160 AC DRIVE SERIES C
POWER DISTRIBUTION OPTION
PROJECT: DRIVE
ACAD
02-09-99
ARS
02-09-99
BAH
02-09-99
L\DM\1336P??
04
1026630
ARS01-19-07
07
02P0068
ARS02-21-02
06
01P0009
ARS01-19-01
05
00P0291
ARS06-16-00
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
A
B
C
D
E
F
G
H
40
41
39
38
37
36
35
28
33
34
32
31
30
29
27
26
25
24
23
22
14
20
19
18
17
16
15
13
12
11
9
10
8
7
6
5
4
2
3
1
21
28
31
30
29
27
26
25
24
23
22
14
20
19
18
17
16
15
13
12
11
9
10
8
7
6
5
4
2
3
1
32
INDEX NO.
REFERENCE DWG.
DATE
APP'D
DATE
DATE
DR.
TITLE:
DWG.
NO.
REV. DATE
ECN NUMBER
LEAD ENG.
SH:
SH:
NEXT
BY
THIS DRAWING IS THE PROPERTY OF
ROCKWELL AUTOMATION, INC. OR ITS
SUBSIDIARIES AND MAY NOT BE COPIED,
USED OR DISCLOSED FOR ANY PURPOSE
EXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
LAMINATED DRAWING MUST BE RE-ISSUED TO SHOP AFTER ECN
REV. STATUS
OF SHEETS
REV.
SHT.
ANALOG SIGNAL FOLLOWER/PRESET SPEED MODEL
WHT
GRAY
BLU
RED
OPTIONAL
EA2
DN2 DEVICE NET PANEL
BLK
EA1
600V
DS1
L2
L3
L1
F2
F3
F1
POWER DISCONNECTING OPTION
DS OPTION
CUSTOMER
DEVICE-NET
CONNECTION
5-PIN CONNECTOR
3130
17-18,
TO
P2C
OPTIONAL
DNSC1
DNSC2
DNBC1
DNBC2
OPTIONS
MX14 OPTION
SELESC
MODULE
OPERATOR INTERFACE
RUN
PROGRAM
REVERSE
FORWARD
17-38
lLINE FILTER
MODULE
RF1
EMC OPTION
LINE FILTER OPTION
AC LINES
1PH, 50/60HZ
AC LINES
3PH, 50/60HZ
LINE
PE
L3
L2
L1
WHEN DS OPTION
IS NOT ORDERED
PROTECTION
PROVIDED BY
OTHERS
MEANS AND
SHORT CIRCUIT
DISCONNECTING
MODULE
LINE FILTER
17-37
MX14 OPTION
1C
L2
17-18
L3
BRAKE
*
IB1C INTERBUS MODULE
PD1C PROFIBUS MODULE
DN2C DEVICENET PANEL
P2C REMOTE KEYPAD MODULE
P1C PROGRAMMER PANEL
RS1C RS232 SERIAL COM
RS1C RS232 SERIAL COM
READY/FAULT PANEL
(OPTIONAL)
(STD)