Owner's manual
Appendix A – Specifications and Accessories
A-2
Table A.3 – Specifications For All Controller Ratings
Input/Output Ratings (All Controller Ratings)
Output Voltage (V) Adjustable from 0V to input voltage
Output Frequency (Hz) 0 to 240 Hertz Programmable
Efficiency (%) 97.5% (Typical)
Transient Protection Standard 2 kV (Optional 6 kV using MOV module). See accessories on page A-5.
Environmental Specifications (All Controller Ratings)
Enclosure IP 20
Ambient Temperature 0_C to 50_C
Storage Temperature –40_C to 85_C
Relative Humidity 0 to 95% (non condensing)
Vibration 1.0 G Operational – 2.5 G Non-operational
Shock 15 G Operational – 30 G Non-operational
Altitude 1,000 m (3,300 ft.) without derating
Control Inputs (All Controller Ratings)
Control Input Type For dry contact closure input – the controller has an internal 12V power supply that provides
10mA (typical) current flow.
Also accepts open collector/solid state inputs (sinking) with maximum leakage current of 50 mA.
Optional 24V DC interface allows use of 24V DC sinking inputs.
See page A-4 for ordering information.
Start, Stop, Forward/Reverse Configurable inputs for 2 or 3 wire control
SW1, SW2, SW3
(Preset Speed Model only)
Configurable Inputs for control of 8 preset speeds and 2 Accel/Decel times
Programmable Input TB3-8 can be configured to select:
Accel/Decel Times
Controller Enable/Disable
Local/Remote
Approvals and Standards Compliance (All Controller Ratings)
Approvals
UL508C CSA 22.2
Designed to meet these standards IEC 146–1–1
FCC Class A
➀
and B
➀
VDE 0871
➀
and 0875
➀
Control Inputs (Analog Signal Follower only – All Controller Ratings)
External Speed Potentiometer 1K to 10K Ohms, 2 Watts Minimum
Analog Input (4 to 20mA) Input lmpedance 250 Ohms
Analog Input (–10 to +10V DC) Input Impedance 100K Ohms
Control Output (All Controller Ratings)
Programmable Output
(Form C Relay contact)
Resistive rating: 0.4A @125V AC, 0.2A @ 230V AC, 2A @ 30V DC
Inductive rating: 0.2A @ 125V AC, 0.1A @ 230V AC, 1A @30V DC
➀
With external components.