6-56 PARAMETER AND VARIABLE DESCRIPTIONS
1557-UM050F-EN-P June 2013
SCANport Output [SCANport output]
Linear number: 399
Minimum value: -4500 rpm
Maximum value: 4500 rpm
Analog Output Scaling: 10 V = 4096 rpm
This variable is the SCANport output, and indicates the motor speed in rpm.
Prior to Rev 4.60/5.00 this variable was located in the Analog I/O group with a linear number of 366.
Not Used [Not used]
Linear number: 400
Minimum value: 0
Maximum value: 65535
Analog Output Scaling: N/A
This is a dummy variable used to represent all non-existent variables in order to satisfy SCANport
requirements.