Manual

B-154 Parameters
1503-UM054C-EN-P June 2013
Operations Since 2 Count Value on IB3
[IB 3 Operations Since 2 Count Value]
Parameter Number: 297,249,201,_,_.
Access rule: Get
Data Type: UDINT
Object Mapping: 0x384-3-40
Group: Diagnostics
Units : -
Minimum Value: 0
Maximum Value: 0xFFFFFF
Default Value: 0
This parameter allows the user to view the number of Operations
sinc e a Reset Counter on IB3 event occurred and transferred the
Since 1 count value to the Since 2 count value. See “Operations
Since” Counter in Chapter 4 for a more detailed description of this
feature.
Date of Operations Since 2 Count Value on IB3
[IB 3 Operations Since 2 Date]
Parameter Number: 298,250,202,_,_.
Access rule: Get
Data Type: DATE
Object Mapping: 0x384-3-41
Group: Diagnostics
Units : -
Minimum Value: 0
Maximum Value: 0xFFFF
Default Value: 0
This parameter allows the user to view the Date for which the
Operations since a Reset Counter on IB3 event occurred and
transferred the Since 1 count value to the Since 2 count value.
See “Operations Since” Counter in Chapter 4 for a more detailed
description of this feature.