Owner's manual

Chapter 2
1500-IN058D-EN-E – June 2013
Equipment Description
Overview This chapter describes the features of the Bulletin 1406 to Bulletin 825 Plus
Conversion Kit.
Operational Requirements Monitoring application parameters and process data of an installation is
very important. Even a slight change in the starting and operating behavior
of the motor can indicate an impending fault. The Bulletin 825 Plus helps
eliminate the potential trouble before major repairs are necessary and loss
of production occurs.
The Bulletin 825 Plus fulfills these requirements by providing the
following protective functions:
High overload, stalling
Underloading
Wrong direction of rotation
However, the Bulletin 825 Plus functionality does not directly correspond to
the Bulletin 1406. Below is a summary of some of the features offered by
the Bulletin 825 Plus. In most cases the 825 Plus provides improved and
additional features/protection.
Function Description Bul. 1406 Parameters Bul. 825 Plus Parameters
Current Transformer (Primary) 25A – 1500A (rating) 0.5 A – 5000 A
Full Load Current (FLC) 15A – 800A 0.5 A – 5000 A
Thermal Overload Protection Yes Yes
Overcurrent Protection No Yes
Allowable Acceleration Time 5s – 60s 1s – 240s
Allowable RTD types
10 Cu, 100 PI,
100 Ni, 120 Ni
10 Cu, 100 PI,
100 Ni, 120 Ni
Number of Winding RTDs 1 – 6 1 – 12 Y
Number of Bearing RTDs 1 – 2 1 – 12 Y
Allowable Number of Starts
1 – 10
(specified time increments)
1 – 15
(starts per hour)
Phase Unbalance Trip Current 5 – 30 (percent of FLC) 5 – 80 (percent of FLC)
Phase Unbalance Alarm Current 5 – 80 (percent of FLC)
Phase Reversal Protection Yes X Ye s
Features require additional 1406-S option card.
Y Total of twelve (12) inputs for winding, bearing or other RTD.