Owner manual
Rockwell Automation Publication GMSI10-UM002D-EN-E - August 2012 51
The Enpac 2500 Data Collector Chapter 1
Before performing the 3.10 firmware upgrade, take note of the modules installed
on the Enpac 2500 data collector.
1. After downloading the Enpac 2500 3.10 Upgrade .zip file as instructed in
Operating System Update Procedures
on page 50, follow these
instructions.
2. Connect your data collector to your computer by using the USB
connection.
3. Start Microsoft ActiveSync to be connected to the data collector.
4. Extract the .zip file.
5. Double-click the OS Loader.msi file.
TIP
To confirm which modules that are installed and the version by press F3 (About) on the
Main Screen.
Table 12 - Data Collector Modules
Cat. No. Module Version
1441-PEN25-MOD-BAL Balancing Upgrade
1441-PEN25-MOD-BMP Bump Test
1441-PEN25-MOD-FRF FRF - Frequency Response Function
1441-PEN25-MOD-RUCD RuCD - RunUp CoastDown
1441-PEN25-MOD-REC Recorder