Owner manual

226 Rockwell Automation Publication GMSI10-UM002D-EN-E - August 2012
Chapter 8 Balancing Application
6. When the values stabilize, press READ/OK to complete the
measurement.
The following message appears asking if the trial weight is still attached to
plane 1.
7. Press F2 (Yes) if the weight is still attached to the rotor. Press F3 (No) if the
weight has been removed from the rotor in plane 1.
8. Shut down the machine. Continue the balancing procedure in the next
section.
TIP
The green status indicator illuminates when the
measurement is complete.
Refer to
Status Indicators on page 25.
IMPORTANT
Anytime during the initial run, you can do the following:
Press F4 (Esc) to exit the balancing program.
Press the 0 (Shift) key and F1 (Go to) simultaneously to go back to a
previous step in the balance run.
Refer to
Moving Around in a Balance Run on page 233 for details.
Press F2 (Summary) to display the results in the Vibration Summary
Table.
Refer to
Reviewing Data on page 233 for details.