1 Attributes can only be set while the device is in Program Mode. See the description of the Device Mode Object
for more information.
4-20 mA Output Object
(Class ID 32A
H
)
The 4-20 mA Output Object models the configuration of a 4-20 mA output
signal.
Class Attributes
The 4-20 mA Output Object provides no class attributes.
Instances
There are 2 instances of this object. Instance 1 is associated with the Channel 1
measurement. Instance 2 is associated with the Channel 2 measurement.
9 Get/Set Filter Type USINT The type of tracking filter. 0 = Constant bandwidth
1 = Constant Q
10 Get/Set Bandwidth REAL The bandwidth of the
tracking filter.
0.1 to 25 Hz
11 Get/Set Q REAL The Q of the tracking
filter.
1 to 200
Table C.51 Vector Measurement Object Instance Attributes
Attr ID
Access
Rule Name Data Type Description Semantics
Table C.52 Vector Measurement Object Services
Service
Code Class/Instance Usage Name Description
0E
h
Instance Get_Attribute_Single Returns a single attribute.
10
h
Instance Set_Attribute_Single
Sets a single attribute.