92 DeviceNet Objects
Services
Discrete Input Point Object
(Class ID 08
H
)
The Discrete Input Point Object stores information about the value of the
Setpoint Multiplier signal.
Class Attributes
15 Get Consumed Connection
Path Length
UINT Number of bytes in the
consumed_connection_path attribute.
16 Get Consumed Connection
Path
Array of
USINT
Specifies the Application Object(s) that are
to receive the data consumed by this
Connection Object. See DeviceNet
Specification Volume 1 Appendix I.
17 Get Production Inhibit Time UINT Defines minimum time between new data
production.
Table C.15 Connection Object Instance Attributes
Attr ID
Access
Rule Name Data Type Description
Table C.16 Connection Object Services
Service
Code Class/Instance Usage Name
05
h
Instance Reset
0E
h
Instance Get_Attribute_Single
10
h
Instance Set_Attribute_Single
Table C.17 Discrete Input Object Class Attributes
Attr ID
Access
Rule Name Data Type Description Semantics
1 Get Revision UINT Revision of the
implemented object.