Manual
218 Rockwell Automation Publication 1426-UM001F-EN-P - November 2013
Chapter 9 Communication
CIP Electrical Energy Object
The PowerMonitor 5000 unit supports the following attributes and services of
the Electrical Energy Object, Class Code 0x4F.
Table 36 - Supported Attributes
Electrical Energy
Object Attribute ID
Need in
Implementation
Electrical Energy Object Attribute Name PM5000
Implementation
1 Optional Real Energy Consumed Odometer Supported
2 Optional Real Energy Generated Odometer Supported
3 Conditional Real Energy Net Odometer Supported
4 Optional Reactive Energy Consumed Odometer Supported
5 Optional Reactive Energy Generated Odometer Supported
6 Optional Reactive Energy Net Odometer Supported
7 Optional Apparent Energy Odometer Supported
8 Optional Kiloampere-Hours Odometer Supported
9 Optional Line Frequency Supported
10 Optional L1 Current Supported
11 Optional L2 Current Supported
12 Optional L3 Current Supported
13 Optional Average Current Supported
14 Optional Percent Current Unbalance Supported
15 Optional L1-N Voltage Supported
16 Optional L2-N Voltage Supported
17 Optional L3-N Voltage Supported
18 Optional Average L-N Voltage Supported
19 Optional L1-L2 Voltage Supported
20 Optional L2-L3 Voltage Supported
21 Optional L3-L1 Voltage Supported
22 Optional Average L-L Voltage Supported
23 Optional Percent Voltage Unbalance Supported
24 Optional L1 Real Power Supported
25 Optional L2 Real Power Supported
26 Optional L3 Real Power Supported
27 Conditional Total Real Power Supported
28 Optional L1 Reactive Power Supported
29 Optional L2 Reactive Power Supported
30 Optional L3 Reactive Power Supported
31 Optional Total Reactive Power Supported
32 Optional L1 Apparent Power Supported
33 Optional L2 Apparent Power Supported
34 Optional L3 Apparent Power Supported
35 Optional Total Apparent Power Supported