User Manual
Immersion Temperature Transmitter 5
Publication 1414-IN008A-EN-P - October 2005
Repeat these steps until no further adjustment is required.
Specifications
Immersion Temperature Transmitter Specifications
Specification Value
Standard Length 4”
Operating Temperature Range -40 … 105 ºC (-40 … 221 ºF)
Ambient Temperature Range 0 … 70°C (32 … 158°F)
Wiring Connections Terminal Blocks
Enclosures ABS, Metal or Weatherproof
Sensor Types 1000 Ω platinum Class A 0.15°C , Class B 0.3°C