3.6 TroubleshootingLSIG-MMunits
Thefollowingtablelistsaseriesoftypicalserviceconditions,tohelpyouunderstandandsolvehypotheticalfaultsormalfunctions.
N.B.:
1. Beforeconsultingthefollowingtable,checkforanyerrormessagesappearingforsomesecondsonthedisplay.
2. FNindicatesnormaloperationoftherelease.
3. Whenthesuggestionsproposeddonotleadtoasolutionoftheproblem,pleasecontactABBSACEassistanceservice.
No. Situation Possible causes Suggestions
1 Triptestcannotberun 1.Busbarcurrentis>0 1.FN
2.TheTCisnotconnected 2.Checkmessagesonthedisplay
2 Triptimeslower 1.Thresholdtoolow 1.Correctthreshold
thanexpected 2.Curvetoolow 2.Correctcurve
3.Thermalmemoryenabled 3.Excludeifnotnecessary
4.Incorrectneutralselection 4.CorrectNeutralselection
3 Triptimeshigher 1.Thresholdtoohigh 1.Correctthreshold
thanexpected 2.Curvetoohigh 2.Correctcurve
3.CurveI
2
tenabled 3.Excludeifnotnecessary
4.Incorrectneutralselection 4.CorrectNeutralselection
4 Rapidtrip,withI3=Off Iinsttripped FNshort-circuitwithhighI
5 Highearthfaultcurrentvalue, 1.Incorrectselectionofsensor 1.Setint.orext.sensor
butnotriptakesplace 2.FunctionGpreventedwithI>4In 2.FN
6 Displayoff 1NoVauxandcurrentand/or 1.FN,see3.1.2.1
voltageisbelowtheminimumvalue.
2.Temperatureoff-range 2.FN,see3.1.9.6
7 Thedisplayisnotback-lit Currentand/orvoltagesbelowthe FN
limitforlightingthedisplay
8 ReadingofIincorrect Currentbelowtheminimum FN
thresholdthatcanbedisplayed
9 Message“” Functiondisabledordataoff-range FN
insteadofexpecteddata
10 Expectedtripdoesnottakeplace Tripfunctiondisabled FNenabletripifnecessary
11 Noactivationofprotection ValuesofIoutofrange FN,see3.1.9.3
UnbalanceU
12 Nodisplayof NoVaux,buffercapacitor FN,see3.4.6.1
openingdata isdischarged
13 Thepasswordisnotrequested Thepasswordhasbeendisabled FN,re-enterthepasswordwithavalue
otherthan0000
14 Impossibletochangeany Releaseinanalarmsituation FN
parameter
15 Message“Temp.Sensor”or Possiblefaultinsidetherelay ContactAB
“Start-up”
18 InvalidDate 1.Firstinstallation FNsee3.3.3.
2.Informationlostduetopower
failure
19 Untimelytrip see3.5.2
20 LEDlighting see3.5.1
21 Nopossibilitytochange 1.Relayisremotelyset 1.Settolocal
language 2.TheCBisnotopen 2.OpenCB
3.Vauxorbatteryunit 3.Powertherelay