Installation Instructions Owner's manual
Publication 1403-IN005A-EN-P
C-10 Sample Ladder Listing
Rung 2:5
Initialize the sequencer for run
mode. Same functionality as rungs
2:0 and 2:1.
Rung 2:6
This is the main block transfer
sequencer. The sequencer output
word, N9:0, is updated whenever
the previous block transfer is done
or fails.
Initialize for appropriate mode
0005
B3:0
2
Run mode
OSR
B3:18
14
One-shot 3
COP
CopyFile
Source #N13:0
Dest #N10:0
Length 18
MOV
Move
Source 17
17<
Dest R6:0.LEN
17<
Initialize Sequencer
length
CLR
Clear
Dest R6:0.POS
1<
Initialize sequencer
position
MOV
Move
Source N10:0
0<
Dest N9:0
40<
Initialize sequencer
address
Main block transfer sequencer
0006
N[N9:0]:0
13
BT done bit
N[N9:0]:0
12
BT error bit
R6:0
T4:1
EN
DN
EN
DN
SQO
Sequencer Output
File #N10:0
Mask 0FFFFh
Dest N9:0
Control R6:0
Length 17<
Position 1<