Installation Instructions Manual
Publication 1403-IN054B-EN-P - August 2001
B-14 DeviceNet Data Tables
Instance 10 Attributes (DeviceNet Communication Configuration
Read)
Assembly Structure
Common Services
Instance 11 Attributes (Metering voltage, current, and frequency
results)
Assembly Structure
Attribute ID Access
Rule
Name DeviceNet Data Type
3 Get Data Structure of
10 bytes (5 Words)
Param # Parameter name Data type #bytes Master Module Range Default
Setting
Word No.
1 Password Int 2 Always returns –1 1
2 Node address Int 2 0 to 63 (DeviceNet V1)
0 to 64 (DeviceNet V2)
(1)
63 2
3 Baud rate Int 2 0 = 125k
1 = 250k
2 = 500k
3 = Auto (DeviceNet V2 only)
4 = Programmable (DeviceNet V2 only)
125k bps 3
4 Bus off interrupt Int 2 Action to take when a BOI occurs:
0: hold CAN chip in reset
1: reset CAN chip and continue
communicating
04
5 Reserved Int 2 0 5
(1) Node address 64 enables remote node address programming; there is no actual node address of 64 defined for DeviceNet.
Service
Code
Service Name
0Ehex Get_Attributes_Single
Attribute ID Access
Rule
Name DeviceNet Data Type
3 Get Data Structure of
58 bytes (29 Words)
Param # Parameter name Data type #bytes Master Module Range Word No.
1 L1 current Float 4
0.0 to 9999x10
21
amps
1
2
2 L2 current Float 4
0.0 to 9999x10
21
amps
3
4