Installation Instructions Manual

Publication 1403-IN054B-EN-P - August 2001
DeviceNet Data Tables B-75
533
21
st
harmonic
Float 4 See Instance 43, parameter 11 (phase angle for V2)
534
22
nd
harmonic
Float 4 See Instance 42, parameter 1 (phase angle for V2)
535
23
rd
harmonic
Float 4 See Instance 44, parameter 1 (phase angle for V2)
536
24
th
harmonic
Float 4 See Instance 42, parameter 2 (phase angle for V2)
537
25
th
harmonic
Float 4 See Instance 44, parameter 2 (phase angle for V2)
538
26
th
harmonic
Float 4 See Instance 42, parameter 3 (phase angle for V2)
539
27
th
harmonic
Float 4 See Instance 44, parameter 3 (phase angle for V2)
540
28
th
harmonic
Float 4 See Instance 42, parameter 4 (phase angle for V2)
541
29
th
harmonic
Float 4 See Instance 44, parameter 4 (phase angle for V2)
542
30
th
harmonic
Float 4 See Instance 42, parameter 5 (phase angle for V2)
543
31
st
harmonic
Float 4 See Instance 44, parameter 5 (phase angle for V2)
544
32
nd
harmonic
Float 4 See Instance 42, parameter 6 (phase angle for V2)
545
33
rd
harmonic
Float 4 See Instance 44, parameter 6 (phase angle for V2)
546
34
th
harmonic
Float 4 See Instance 42, parameter 7 (phase angle for V2)
547
35
th
harmonic
Float 4 See Instance 44, parameter 7 (phase angle for V2)
548
36
th
harmonic
Float 4 See Instance 42, parameter 8 (phase angle for V2)
549
37
th
harmonic
Float 4 See Instance 44, parameter 8 (phase angle for V2)
550
38
th
harmonic
Float 4 See Instance 42, parameter 9 (phase angle for V2)
551
39
th
harmonic
Float 4 See Instance 44, parameter 9 (phase angle for V2)
552
40
th
harmonic
Float 4 See Instance 42, parameter 10 (phase angle for V2)
553
41
st
harmonic
Float 4 See Instance 44, parameter 10 (phase angle for V2)
554 IEEE THD Float 4 See Instance 40, parameter 1 (for I2)
555 IEC thd Float 4 See Instance 40, parameter 2 (for I2)
556 TIF Float 4 See Instance 40, parameter 3 (for I2)
557 Crest factor Float 4 See Instance 40, parameter 4 (for I2)
558 K-factor Float 4 See Instance 40, parameter 5 (for I2)
559 IEEE 519 pass/fail Int 4 See Instance 40, parameter 6 (for I2)
560 Fundamental Float 4 See Instance 43, parameter 1 (% harmonic distortion for I2)
561
2
nd
harmonic
Float 4 See Instance 41, parameter 2 (% harmonic distortion for I2)
562
3
rd
harmonic
Float 4 See Instance 43, parameter 2 (% harmonic distortion for I2)
563
4
th
harmonic
Float 4 See Instance 41, parameter 3 (% harmonic distortion for I2)
564
5
th
harmonic
Float 4 See Instance 43, parameter 3 (% harmonic distortion for I2)
565
6
th
harmonic
Float 4 See Instance 41, parameter 4 (% harmonic distortion for I2)
566
7
th
harmonic
Float 4 See Instance 43, parameter 4 (% harmonic distortion for I2)
567
8
th
harmonic
Float 4 See Instance 41, parameter 5 (% harmonic distortion for I2)
568
9
th
harmonic
Float 4 See Instance 43, parameter 5 (% harmonic distortion for I2)
569
10
th
harmonic
Float 4 See Instance 41, parameter 6 (% harmonic distortion for I2)
570
11
th
harmonic
Float 4 See Instance 43, parameter 6 (% harmonic distortion for I2)
571
12
th
harmonic
Float 4 See Instance 41, parameter 7 (% harmonic distortion for I2)
Param # Parameter name Data type #bytes Comment