Installation Instructions Powermonitor II Lithium Battery Catalog Number 1403-BA Topic Page Important User Information 2 Before You Begin 3 Handling 3 Storing of Undischarged Lithium Batteries 3 Transporting of Undischarged Lithium Batteries 4 Disposal of Discharged Lithium Batteries 5 Documentation 5 Labeling 5 Install or Replace the Lithium Battery 6
Powermonitor II Lithium Battery Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://literature.rockwellautomation.com) describes some important differences between solid state equipment and hard-wired electromechanical devices.
Powermonitor II Lithium Battery 3 Before You Begin Follow the information below to ensure lithium battery operation and reduce hazards to personnel. For more information on transporting, labeling, storing, and documentation, please see the Code of Federal Regulations, Title 49. Handling Follow these guidelines when handling the lithium battery. • Use only for intended purpose.
Powermonitor II Lithium Battery Transporting of Undischarged Lithium Batteries Procedures for the transportation of lithium batteries within the United States are specified by the Department of Transportation (DOT) in the Code of Federal Regulations (CFR), Title 49, Transportation and the International Air Transport Association (IATA), Dangerous Goods Regulations.
Powermonitor II Lithium Battery 5 Disposal of Discharged Lithium Batteries In the United States, transportation of depleted lithium batteries for disposal is controlled by Code of Federal Regulations, Title 49. Depleted lithium batteries are defined as the extent that the open circuit voltage is less than the lower of: • 2.
Powermonitor II Lithium Battery Install or Replace the Lithium Battery Follow these steps to remove and install the lithium battery in a Bulletin 1403 Master Module. ATTENTION This procedure may be conducted with full electrical power applied to the Master Module. Use extreme caution when installing the lithium battery into your Bulletin 1403 Master Module. Failure to use extreme caution can lead to personal injury or death, property damage, or economic loss.
Powermonitor II Lithium Battery 7 3. Gently pull upwards on the battery extractor tab to remove the battery from its holder. ATTENTION The battery is held under pressure within its holder and may be forcefully ejected upon extraction. 4. Install the lithium battery noting the correct polarity within the battery holder. Note that the battery must be installed over top of the battery extractor flap. The lithium battery should be held securely in place within the battery holder. 5.
6. Reinstall the closure plate on the top face of the Master Module. 7. Send a command to reset the real time clock and clear the battery usage counter using the Display Module or the Communication Card. ATTENTION ATTENTION Risk of fire or burns. Do not recharge, disassemble, heat above 100 °C (212 °F), or incinerate. Keep battery out of reach of children and in original package until ready to use. Dispose of used batteries promptly. Never put batteries in mouth.