Instruction Manual

306 Variables and Flags Assignment and Request Commands Motion
Publication 1398-PM601A-EN-P October 2000
HOST MODE
Motion
The commands contained in this table are used to control the effect of motion. They do not cause any
motion, they set conditions that affect motion. See also Motion Execution Commands on page 295.
Outputs Analog and Digital
The commands in this table cover all digital and analog outputs including the monitor output and out-
puts located on optional I/O Expansion Cards.
Command Description Flag/
Variable
Read/
Write
Personality
Module
GEAR Current value of the gear ratio. V R/W N
GEAREN TRUE if the GEAR is enabled. F R/W N
ROTT Rotation direction for tracking function. F R/W N
SLEW Limit for output of gear. V R/W Y #
SLEWEN Enables the slew rate limit for the gear out-
put.
FR/WY#
TRACKINGEXT-
POSSELECT
TRUE if the Tracking function applies after
Gear and Slew functions. FALSE if the
Tracking function applies before Gear and
Slew functions.
FR/WN
TRACKINGMODE Sets the mode for the Tracking function:
0 = Off
1 = Ratchet mode
2 = Anti-backlash mode
VR/WN
TRACKING-
SYNCED
TRUE if the Tracking function is not dis-
abling follower motion.
FRN
Command Description Flag/
Variable
Read/
Write
Personality
Module
ATHOME TRUE to enable At Home output. F R/W Y
DAC1 Default DAC1 output value. (Note that the runtime
value of DAC1 is write only.)
VR/WY#
DISERR TRUE for ERROR output ON when disabled. F R/W Y
ERLY TRUE if the DRIVE ENABLED relay is closed. The
status of these relays are normally handled internally
and these commands are used only in diagnostics
modes. The PLC logic of the drive should be disabled
(XPLC TRUE) before directly accessing either of
these relays.
Note: The relay status is available in the S (status)
command.
FRN
ERREN TRUE to enable ERROR output. F R/W Y
IPEN TRUE to enable In-Position output. F R/W Y