Instruction Manual
214 Language Reference • Reference
Publication 1398-PM601A-EN-P — October 2000
WORDS
HLIMITS
Travel Limits Enabled Flag System
Purpose Set if travel limit inputs are enabled.
Syntax variable = HLIMITS
variable The variable may be a nonvolatile flag Bn, a volatile flag Fn, or
another system flag.
Remarks
See Also DISLIM
Example
F4 = HLIMITS
IF HLIMITS = ON …
HOFFS
Home Offset Home
Purpose Set the Home Offset. Home Offset specifies the distance from the encoder index, or
home switch if there is no index, to the home position. The sign specifies the direction
of the offset.
Syntax HOFFS = value
variable = HOFFS
value The Home Offset is entered in user units. User units are defined
by the SCALE parameter. Va l ue can be a constant, a nonvolatile
variable Gn, a volatile variable Vn, or a system variable.
variable The variable can be a nonvolatile variable Gn, a volatile vari-
able Vn, or a system variable.
Remarks The default home program finds the home position based on the home switch and/or
the encoder index. Once this position is found, an incremental move is made with a
distance of HOFFS. Home position (zero) is then defined. A detailed description of the
home program is in Appendix A.
Changes made to this variable by a program are only in effect while the program is
running. When the program ends it will return to the value stored in the Personality
Module. If no change is made to this variable by the program, the value in the Person-
ality Module is used. The value in the Personality Module is set in the Parameter
menu, Velocity/Accel dialog box.
See Also DP, DH, Appendix A, System Programs
Example
HOFFS = 1.5
V2 = HOFFS