Instruction Manual

Language Reference Reference 203
Publication 1398-PM601A-EN-P October 2000
WORDS
Fn
Volatile User Flag Variable
Purpose Set a user flag ON or OFF with another flag, or a constant.
Syntax Fn = ON/OFF/Fn/Bm
variable = Fn
n, m The number of the flag. n = 1, 2, 3, ..., 64. m = 1, 2, 3, , 8
variable Variable may be a nonvolatile flag Bn, a volatile flag Fn, or a
system flag.
Remarks The changes made to Fn remain in effect as long as power is maintained. On power-up
or HRESET all Fn flags are set to OFF. If a flag needs to be maintained during a power
failure use a Bn flag. Changes made to Fn flags by one program will be seen by other
programs.
TIP: Variables can be assigned names using the ASSIGN command and then refer-
enced by those names to make the program easier to read.
See Also Gn, Bn, Vn
Example
F1 = ON
F2 = OFF
IF F1 ON MOVD = 5