WORDS
ALL
All Outputs Outputs
Purpose Turn all outputs ON or OFF. Assigned outputs such as Program Running, Error, At
Home, Home Sequence Complete, or In-Position are not affected unless disabled from
the Parameters menu, Outputs dialog box.
Syntax ALL ON/OFF
ON Turn all outputs ON. Outputs are current sinking type. ON turns
on the transistor and pulls the output to 24V common.
OFF Turn all outputs OFF. Outputs are current sinking type. OFF
turns off the transistor and leaves the outputs floating. There is
no internal pull-up.
Remarks Refer to the appropriate ULTRA Plus or IQ-Series Installation Manual (1398-5.1, Part
Number 0013-1027-004 or Part Number 0013-1022-004) for electrical specifications.
See Also On = ON/OFF/Fn
Example
ALL ON
ALL OFF