User Manual

Publication 1398-5.0 – October 1998
8-20 Application and Configuration Examples
14. Choose the Drive Parameters command icon from the Drive
window and then select the
Follower tab.
15. Enter an appropriate
G
ear Ratio as the Follower Input. The
default Gear Ratio is 1:1 (motor encoder pulses:master pulses). If
a Gear Ratio of 3:1 is entered, the motor is moved 3 encoder
pulses for every incoming step pulse.
16. Choose
Close to exit the Drive Parameters window.
17. Select the
I/O Configuration command icon from the Drive Win-
dow.
18. Select an appropriate digital input from the pull-down lists avail-
able as Digital Input Assignments in the I/O Configuration win-
dow.
For example:
Follower Enable as Input 1
Not Assigned as Inputs 2 through 4.
Not Assigned as Outputs 1 through 4.
19. Choose
Close to exit the I/O Configuration window.
Tuning
1. Choose the Tuning command icon from the Drive window.
2. Select
A
utoTune from the Tuning mode group.
3. Select the appropriate values for the following Auto Tune com-
mands:
Distance and
Step Current.
4. Select the appropriate entry for the Motor Direction:
BiDirectional,
Forward Only or
Reverse Only.
Note: Do not attempt to Auto Tune systems that have gravitational
effects. The ULTRA 200 Series will not hold initial position.