Installation Manual User guide
Publication 1398-5.2 – PDF 1997
6-8 Interfaces
● Dedicated relay outputs
● Selectable transistor based outputs
Both types support 12-24 VDC logic interfaces:
Dedicated Relay Outputs
BRAKE/DRIVE ENABLED and DRIVE READY. Each output is a
normally open relay. The relays are rated for 1 Amp at 30 VDC.
Note: The Brake contacts may be used to control 24VDC brakes on
Allen-Bradley motors with a 4” frame or smaller. A user provided relay
may be driven by these outputs if higher power levels are required. Refer
to Figure 6.10 for examples.