Installation Manual User guide

Publication 1398-5.2 – PDF 1997
Installation 5-3
Figure 5.1 1398-DDM-005 and -005X Mounting Dimensions
Table 5.1: 1398-DDM-005 and -005X Mounting Dimensions
Dimension Dimension
mm inches mm inches
A 198.12 7.80 B 72.60 2.86
A1 184.9 7.28 B1 65.02 2.56
A2 6.35 0.25 B2 38.10 1.50
A3 13.0 0.51 B3 18.54 0.73
A4 60.7 2.39 B4 13.21 0.52
A5 94.49 3.72 B5 5.58 0.22
A6
a
5.0 0.20
A7 22.10 0.87 C 146.05 5.75
A8 31.75 1.25 C1 129.03 5.08
A9 8.64 0.34
A10 31.75 1.25
A11 57.15 2.25
a. Power Cable bracket extends up to 20 mm (0.80 inch)
C
C1
B
B1
B2
B4
B3
A
A1
A2
A3
A4
A6
A7
A8
A9
A10
A11
A5
C
C1
B
B1
B2
B4
B3
A
A1
A2
A3
A4
A6
A7
A8
A9
A10
A11
A5
Minimum unobstructed surrounding space
for cooling and exhaust air
Above 50.8 mm (2 inches)
Below 50.8 mm (2 inches)
Sides 12.5 mm (0.5 inches)
for cable bend radius
Front 76.2 mm (3 inches)