Installation Manual User guide
Publication 1398-5.2 – PDF 1997
Application and Configuration Examples 8-33
9. If the message box appears that a motor must be selected, select
OK. The Drive Setup window is displayed with Motor Model
selection parameter active. The motor may be selected from the
drop down box. If this message box does not appear, the motor
displayed in the Motor Model box was previously selected.
10. Select or verify the correct motor model number from the drop
down Motor Model list.
11. If a message advises that the drive must be reset, choose
Yes.
12. Select
Indexing as the Operation Mode for the drive.
13. Choose
Close to exit the Drive Set Up window.
14. Choose the
Drive Parameters command icon from the Drive
window and then select the
Indexing tab.
15. Enter the following values for Index 0
. Refer to “Incremental
Indexing Examples” on page 8-30 for examples of Single and
Batched Incremental Indexing profiles.
16. Choose
Close to exit the Drive Parameters window.
17. Verify the Status indicator is green.
18. Select the
I/O Configuration command icon from the Drive Win-
dow.
19. Select an appropriate digital input from the pull-down lists avail-
able as Digital Input Assignments in the I/O Configuration win-
dow.
For example:
•
Start Index as Input 1
•
Not Assigned as Inputs 2 through 3.
Single Move Settings Batched Move Settings
Incremental as Mode Incremental as Mode
8000 as Distance 8000 as Distance
1 as the Batch Count 3 as the Batch Count
0 as Dwell 1000 as Dwell
Appropriate values for
Acceleration and Decelera-
tion
Appropriate values for
Acceleration and Decelera-
tion