Instruction Manual
Using SCANport Capabilities D–13
Publication 1397-5.0 — June, 2001
Use the tables on the following pages to record your particular
parameter value setting for the current application.
No. Name Default Value No. Name Default Value
1 Anlg In 1 0 40 Maximum Current 150%
2 Anlg In 2 0 41 Max Motor Speed 500
3 Anlg In 3 0 42 Max Process Speed 500
4 Anlg In 4 0 43 Min Process Speed 250
5 Armature Voltage 0 44 Motor Field Amps 0.01
6 Cur Loop Fdbk 0 45 Motor Arm Amps 8
7 Cur Loop Error 0 46 Motor Arm Volts 240
8 Cur Loop Ref 0 47 Anlg Tach V/100 18.0 V
9 Draw Percent Out 0 48 Encoder PPR 18
10 Field Feedback 0 49 Encoder Quad On
11 Frequency In 0 50 Nominal AC Freq 50 or 60 Hz
12 Jog Ramp Output 0 51 Nominal AC Volts 230 VAC
13 Monitor 1 Output 1 52 Auto Tune Type
14 Monitor 2 Output 53 Future Use
15 MOP Output 0 54 Future Use
16 OCL Enable TP 1 55 Future Use
17 OCL Feedback 0 56 Future Use
18 OCL Output 0 57 Anlg Tach Gain 1.000
19 OCL Ramp Output 0 58 Anlg Tach Zero 0
20 OCL Reference TP 0 59 Arm Voltage Gain 1.0
21 Spd Loop Error 0 60 Arm Voltage Zero 0
22 Spd Loop Fdbk 0 61 Cur Loop K–Fdbk 1.00
23 Spd Loop Lag Out 0 62 Cur Lp Lead Freq 100
24 Spd Loop Output 0 63 Cur Loop Kp 0.250
25 Spd Loop Ref 0 64 Cur Loop Rate Lim 40
26 Spd Src Output 0 65 Future Use
27 Spd Ramp In TP 0 66 IR Compensation 0%
28 Spd Ramp Output 0 67 Pos Cur Lim 150%
29 Speed Pot 0 68 Neg Cur Lim 150%
30 Trim Output 0 69 Pos Cur Lim Src Register
31 Torque Reference 0 70 Neg Cur Lim Src Register
32 Future Use 71 PLL Max Error 2
33 Future Use 72 Spd Lead Lag Freq 1.00
34 Future Use 73 Lead Lag Ratio 2
35 Future Use 74 Spd Lead Lag Type Bypass
36 CT Turns Ratio 32767 75 Spd Lp Lag Freq 3.00
37 Accel Time 50 76 Spd Lp Lag Type On
38 Decel Time 50 77 Spd Lp Lead Freq 3.00
39 Feedback Type 0 (Arm Volt) 78 Spd Loop Kp 4.40
User Parameter Values