575Programming Parameters
Publication 1397-5.0 June, 2001
OWNERS
[Stop Owner] P.214
This parameter displays which adapters are
presently issuing a valid stop command.
Display/Drive Units: Numeric/Text
Parameter Range: Bit # Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6
Parameter Type: Read Only
Group: Owners
Minimum Value: 00000000000000000
Factory Default: 00000000000000000
Maximum Value: 0000000001111111
[Start Owner] P.215
This parameter displays which adapters are
presently issuing a valid run command.
Display/Drive Units: Numeric/Text
Parameter Range: Bit #
Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6
Parameter Type: Read Only
Group: Owners
Minimum Value: 0000000000000000
Factory Default: 0000000000000000
Maximum Value: 0000000001111111
[Direction Owner] P.216
This parameter displays which adapter
currently has exclusive control of direction
changes.
Display/Drive Units: Numeric/Text
Parameter Range: Bit #
Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6
Parameter Type: Read Only
Group: Owners
Minimum Value: 0000000000000000
Factory Default: 0000000000000000
Maximum Value: 0000000001111111